This website consolidates products from SEE, Caneco, and ETAP.
Any question or comment? Please contact us.
+33 (0)5 62 74 36 36

V8R3

Release notes

Home  ›  Release notes  ›  V8R3

SEE Electrical SEE ELECTRICAL V8R3


New features

Themes

basic

In order to enhance user experience and add SEE Electrical modern look, new themes were introduced. It is possible now to choose one of new twelve application looks making it even more customizable.

Possibility to reset user interface to default settings

basic

In Colour and Layout tab of System Settings, it is possible now to reset user interface to default settings provided with SEE Electrical. Command will remove all customized settings such as dialogs positions, shortcuts, quick access menu entries and interface colour.

Defining Workspace Information on first open

basic

Process of creating new workspace contains one additional step where after selecting workspace template it is possible to define all project attributes. List contains all attributes defined for template that is used including inserted values.

Printing by Functions or Locations

standard

It is possible now to print drawings according to selected Functions or Locations. Printing process includes all drawings regardless their type and orders them according to Workspace structure. Drawings without Function/Location assigned cannot be printed using this mode.

Browsing drawings in Print Preview

basic

If Print Preview functionality is executed from File menu, it is possible now to use Next Page and Previous Page commands to navigate through all drawings within current workspace. If this functionality was executed from printing dialog then navigation is possible only within selection (Function selection, Print List etc).

Two Page command in Print Preview

basic

If Print Preview functionality is executed on database view with many columns (where it is not possible to print all of them using selected page size), the new command Two Page is enabled. Executing it allows to display two pages next to each other so all data is displayed in one preview.

Update of types definition after performing modification in Equipment Database

standard

After performing modification to any type in Equipment Database, user is prompt to update type definition stored in current project.

Symbol modification lock

basic

In About SEE Electrical dialog new button Review Release Notes was added that allows to open this document without need to look for it in program files.

Display of first type only

basic

It is possible now to show only first type on a drawing. In order to do that, it’s required to select First type only option in Show column available for Type attribute (Component Properties dialog).

Possibility to choose CatalogueID or TypeID attributes from SEE Web Catalogue as Type

standard

In Properties of Equipment Database, it is possible now to define which out of two SWeC attributes will be used identify downloaded codes.

Workspace attributes in 3D Panel drawings

standard

All nonempty Project attributes are being displayed in 3D Panel drawings now.

Hiding components excluded from lists

standard

Pick List and Complete functionalities received additional option Hide components excluded from lists which if enabled, applies additional filter. This filter excludes all components that have Component in list attribute defined as “excluded from BOM/parts” or “only as target”.

Easier access to Release Notes

basic

In About SEE Electrical dialog new button Review Release Notes was added that allows to open this document without need to look for it in program files.

SEE Gen e-doc integration

basic

With V8R3 we added a possibility to export workspaces to SEE Gen e-doc service using Export… > Workspace to SEE Gen e-doc command. After executing this command, zip archive named after project will be prepared and placed in “C:\Users\Public\Documents\IGE+XAO\SEE Electrical\V8R3\JsonFiles”. If you are interested in more information about this service please contact your local IGE+XAO representative.

Link Types

standard

Functionality of Link Types introduced in V8R2 was enhanced. It is possible now to freely define and customize Link Types by changing names, excluding from auto numbering, and defining how they will appear on generated Terminal Strip.

Support for Connectors in 3D Panel

standard

All information defined for connectors are being sent to 3D Panel module so it is possible to insert and route them like all other types of components.

Rail and Cable Channels not in list

basic

Component not in list attribute was added to Cable Channel and Rail components inserted on Cabinets drawings allowing to easily manage graphical list generation as well as Complete and Pick List functionalities.

Auto-rotation of symbols inserted using Pick List

standard

If option Auto Rotate available on ribbon is enabled, symbols being inserted are rotated automatically to existing walls and objects same way as they would be inserted from Symbols pane.

Possibility to select symbols using advanced filters

basic

New function Select Symbols allows to easily select many symbols that match user defined rules. To user’s disposition we delegated most used attributes such us Panel Name, Fuse Circuit, Type, Symbol Object Type and more. Additionally, leaving all criteria empty selects all electrical symbols.

Modification of inserted cables in Building Installation

basic

It is possible now to change path of inserted cable using drag and drop functionality on trackers defined by inflection points. All modifications automatically recalculate length of a cable.

Room creation parameters and display options

basic

Possibility to define room creation parameters has been added to Building Installation Properties dialog as new Room tab. It is possible now to customize line width, size, and style as well as brush colour and style. In addition to that, it is possible to change visibility of all elements that define rooms such as name, description, and graphics.

Component numbering for Building Installation drawings

basic

Component number available in Building Installation Properties dialog allows now to define syntax of Product attribute assignment using one of existing methods or creating custom one.

Symbol Display Group for Cables

basic

Cables connected to symbols inherit Symbol Display Group attribute and its visibility.

Control of attributes rearrangement

basic

New attribute Rearrange Symbol Tags allows to define whether all visible attributes in Building Installation drawings must be rearranged according visibility or not.

Possibility to define left and right reference symbol

standard

In Distribution Diagram Properties dialog, it’s possible now to define which symbols are used on the left and right side of a potential.

Mapping of attributes for Distribution Diagrams symbols

standard

If type for a Distribution Diagrams symbol is defined, all crucial attributes such as Rated Voltage, Rated Current, Breaking Capacity, Number of Poles etc are being filled with values from Type Properties (if given type is properly defined).

Possibility to define diagrams layout settings for each panel

standard

In Panel Definition dialog it is possible now to define parameters that are used for diagrams generation of giver panel.

Separation of setting for Intelligent PDF module from Printing settings

basic

Intelligent PDF module commands (Drawing2PDF, Workspace2PDF, PrintList2PDF) were merged into new one named GeneratePDF. All parameters that define PDF file generation were separated from printing and introduced in existing Generate PDF dialog along with Print range known from printing functionality. It is also possible to execute PDF file generation straight from File menu.

Improvements

Enhanced File menu structure

basic

File menu has been remodelled to make it more intuitive for users:

  • New node Export contains all commands that allow to export drawings or whole project to files that cannot be imported back without losing electrical information (PDF, Metafile, DWG/DXF/DXB, SVG).
  • Commands that allows to insert drawings stored in non-native format were moved to Import node.
  • Order of all nodes was adjusted in order to improve ergonomics.

Enhancement of Complete

standard

Complete functionality was highly enhanced by adding additional methods of execution and changing overall workflow. It is possible now to execute Complete functionality on selected elements. If within selection (including graphical elements) there is only one component that can be completed, then process goes straight to symbol selection. If there are more, list of components that can be completed is prefiltered (with possibility to remove filter if required).

Enhancement of Pick List

standard

Pick List dialog displays Description 00 attribute now what allows for easier identification of already inserted components. Additionally, it is possible to define sorting and filters which can be stored and loaded on demand.

Enhancement to Terminal lock

basic

If Terminal symbol is locked (by changing Name Lock attribute to Fully locked), it is no longer possible to change Terminal Number, Terminal Index, Level Name, Level Index and Level Separator attributes. Executing Rename all shown terminal numbers command from Editor, Terminals database will not change attributes that belong to terminals with name lock enabled.

Text position for Function/Location box attributes

standard

It is possible now to define position of text attributes displayed by Function/Location box symbols by navigating to Workspace Properties > General > Function/Location box setup. Available options are; Inside, Outside Left and Outside Top. Additionally, text attributes are not stretched while resizing and automatically rearranged to maintain the best visibility for this type of symbol.

Dimensions excluded from translation

basic

All dimensions inserted using SEE Electrical are excluded from translation now.

Zoom in Print Preview

basic

Levels of magnification used by Zoom In functionality available in Print Preview dialog were modified so it is possible to set it up to 100%, 25% and 12,5%.

Insertion of generated legend table

basic

Insertion method of generated legend symbol has been changed – instead placing legend in 0,0 coordinates, it’s being attached to the cursor allowing for free manipulation before insertion including rotation and scaling (using keyboard shortcuts)

Default folder for legend table

basic

In Building Installation Properties dialog, it is possible now to define folder name where legend symbols are stored what save time spent on browsing symbols each time GenerateLegend command is execute. Defined value is used to prefilter all symbol libraries and display only folders (and their symbols) with a given name.

Default value for Find and Replace

advanced

Default value for Find and Replace functionality available for blocks was changed from “Entire workspace” to “Selected element(s)”.

Scaling drawing using DWG Editor

basic

DWG Editor allows to scale drawings before insertion. It’s possible now to select one of predefined values such as 1:50 or 1:100 in order to speed up this process. Possibility to define custom scale was kept.

Renumbering of multi-level terminals

standard

After executing Renumber all shown terminal number command available in Editor, Terminals, multi-level terminals are treated as one component and renumbered properly.

Creation of ongoing terminals while pasting drawings

advanced

New option Create ongoing terminal numbers if Free is set for Terminal strip naming available in Copy page behaviour dialog allows to automatically renumber terminals while copying pages between projects. Within this option, we defined two different approaches depending on terminal number syntax – only numeric Terminal Number attributes are incremented. If terminal number is empty or alphanumeric, then Terminal Index attribute is incremented instead.

Enhancement of Multicore wires

advanced

Certain limitations of Multicore wires were removed which means that it is possible now to use cross references and Multicore to connect symbols on different pages, define text parameters used for symbol and change Component Code attribute.

Naming of reference symbols for Distribution Diagrams

standard

Naming of reference symbols used in Distribution Diagrams drawings was modified – Product attribute is inherited from panel’s name that reference is generated for and Product Index comes from page number where symbol is initially inserted.

Redesign of Distribution Properties dialog

standard

Due to many different options that are required for Distribution Diagrams module, Distribution Diagrams Properties dialog was redesigned to give a better overview of all settings.