It is possible now to export labels for equipment, wires, cables, and terminals directly to Weidmüller M-Print PRO. This integration requires to predefine M-Print PRO scripts (*.mis files) that translate files exported from SEE Electrical into labelling information and to select those scripts in Label Export Settings dialog available after clicking on Settings button in Label Export main dialog. Then, when Weidmüller is selected as target manufacturer, M-Print PRO’s presents in the system is checked and data exchange occurs. Moreover, it is possible to specify whether labels should be generated, saved in given location or even printed automatically.
It is possible now to export labels for equipment, wires, cables, and terminals directly to WAGO Smart Script (version 4.9.3 or higher). When WAGO is selected as target manufacturer, Smart Script’s presents in the system is checked and data exchange occurs.
New File > Export > Terminals > Weidmüller WMC command allows to export a file that contains all terminals’ manufacturing information for Weidmüller Configurator, which allows to check the design, equip it with additional parts, customize and even order preassembled terminal strips.
New File > Export > Terminals > WAGO Smart Designer command allows to export a file that contains all terminals’ manufacturing information for WAGO Smart Designer, which allows to check the design, equip it with additional parts, customize and even order preassembled terminal strips.
Thanks to File > Import… > BOM from TIA Selection Tool command, it is possible to import an AML file containing configuration created using Siemens TIA Selection Tool. Imported devices are added to the Editor, Components Without Graphic and are accessible through Pick List or Complete commands.
3D Panel module compatible with this version of SEE Electrical is V3R1 SP1 (3.1.1.18). If SEE Electrical 3D Panel+ has been previously installed, it will be updated automatically.
SEE Electrical now supports silent mode execution through the command line. By appending “/silentmode” to the command, the main application will remain hidden, and a progress bar will be displayed until all processes are completed.
The state of the toggle between manufacturers and goods groups display in the Equipment Database is now stored.
Issue where graphical lists were missing when converting projects has been fixed.
Errors which occurred while creating new pages, assigning templates, or inserting new pages has been resolved.
Wire and net numbering functionality has been completely redesigned which eliminates incorrect values generated for certain edge cases.
Translation window properly refreshes when moving out of the screen now.
Cables created with user-defined symbols show all cable cores information in Component Properties
Vector fonts can now be selected in cable and cable core text setup dialogs.
Contact references are now displayed correctly according to the applied option.
Wire directions no longer get removed when moving wires.
Component list available in Intelligent PDF is generated correctly to PDF.
Circuit Diagrams Properties window is begin displayed correctly when no templates can be found in the environment.
Freeze that occurred during using auto connection has been eliminated.
Hierarchical structure of drawings is correctly recovered when using RecoverFromAutoBackup
Inconsistency which occurred during modification of Rearrange symbol Tags attribute during multi selection has been fixed.
Crash that occurred when using the GeneratePDF command while in Safe Mode has been resolved.
When using AutoBackup command and importing pages with same ID, a message listing duplicates is displayed.
Edit in Spreadsheet functionality of DrawingConfigurator and BlockConfigurator commands has been fixed.
Crash that occurred during modification of PLC signal’s Free Connection Text has been resolved.
Graphical issue on workspace tree when pasting pages has been fixed.
Crash that occurred when opening PDF file created by ProClima without any reader installed on the machine has been resolved.
Issue with scaling components inserted on rails has been fixed.
Issue with part numbers not being parsed correctly when component was added to cable’s block has been fixed.