Home Product › Caneco HT
expert-alpi

Caneco HT

Caneco HT enables the design and verification of private medium and high voltage electrical installations in compliance with applicable standards.

Caneco HT

Annual subscription

Calculation of IK1 with IC

Considering the capacitive current IC in the calculation of the phase-to-earth fault IK1.

Standard assigned characteristics for CT and VT out of catalogue

When choosing a CT or VT out of catalogue, a list of normalized values is proposed for each assigned characteristic (Ur, IP/is, Ith, precision power, ALF…)

Integration of a generic protection relay with functions 50/51, 50N/51N,50G/51G

  • Addition of a generic relay with max phase current (50/51) and max zero sequence (50N/51N, 50G/51G) functions.
  • The relay has three thresholds with wide adjustment ranges and very fine pitches.
  • The first threshold may be of DT or IDMT type (13 standardized curves).

Drop-down list of standard voltage choices for network feeders and switchboards

Addition of a list of standardized voltages (according to NF C13-200 standard) for network feeders and switchboards.

Other features

  • Add a box in the “network feeder” window to identify public distribution substations.
  • Add a box for IB (base current) for connection type links such as cables.
  • mproved setting of general protection (in addition to the 0.8*IK2min, apply the 8*IB rule).

New Manufacturer catalogues

  • Fuse: Schneider Electric 2020
  • Relays: ABB : REM 615, RET 615 et REF 620 ranges.
BUY NOW

Overview

Caneco HT enables the design and verification of private medium and high voltage electrical installations in compliance with applicable standards.

In a single solution, it allows for: cable calculation and sizing, power electrical schematics: SLD and BSLD, cell verification, selectivity and coordination of protections, and automatic generation of calculation notes.




Overview

What's new?


Calculation of IK1 with IC

Considering the capacitive current IC in the calculation of the phase-to-earth fault IK1.

Standard assigned characteristics for CT and VT out of catalogue

When choosing a CT or VT out of catalogue, a list of normalized values is proposed for each assigned characteristic (Ur, IP/is, Ith, precision power, ALF…)

 


Integration of a generic protection relay

Integration of a generic protection relay with functions 50/51, 50N/51N,50G/51G.

Features

New features

+
Calculation of IK1 with IC

Considering the capacitive current IC in the calculation of the phase-to-earth fault IK1.

Standard assigned characteristics for CT and VT out of catalogue

When choosing a CT or VT out of catalogue, a list of normalized values is proposed for each assigned characteristic (Ur, IP/is, Ith, precision power, ALF…)

Integration of a generic protection relay with functions 50/51, 50N/51N,50G/51G

  • Addition of a generic relay with max phase current (50/51) and max zero sequence (50N/51N, 50G/51G) functions.
  • The relay has three thresholds with wide adjustment ranges and very fine pitches.
  • The first threshold may be of DT or IDMT type (13 standardized curves).


Drop-down list of standard voltage choices for network feeders and switchboards

Addition of a list of standardized voltages (according to NF C13-200 standard) for network feeders and switchboards.

Other features

  • Add a box in the "network feeder" window to identify public distribution substations.
  • Add a box for IB (base current) for connection type links such as cables.
  • mproved setting of general protection (in addition to the 0.8*IK2min, apply the 8*IB rule).


New Manufacturer catalogues

  • Fuse: Schneider Electric 2020
  • Relays: ABB : REM 615, RET 615 et REF 620 ranges.

General features

+
KEY FEATURES:

Calculations and sizing of electrical equipment

  • Caneco HT performs calculations of admissible currents
  • Caneco HT enables the calculation of Peak short-circuit currents (effective value and peak value) and minimum short-circuit currents (between phases and earth fault), homopolar and capacitive currents
  • Caneco HT calculates voltage drops anywhere in the installation, depending on the impact of loads on the electrical grid
  • It also enables you to size and verify cable cross-sections


Convenient for simple and complex network architectures

  • With Caneco HT, you can determine the operating configurations of the installation, whether they are displayed in a hierarchical or a loop network
  • Calculations take into account the worst-case conditions, in order to ensure compliance of the network with applicable standards


Automatic production of documents

  • Caneco HT produces calculation files and documents with all the equipment specifications to comply with the main standards: calculation notes, network single-line diagrams, protection settings lists, selectivity curves, etc.


ADVANTAGES:

Quality and compliance:

  • Caneco HT performs electrical sizing in compliance with national and international applicable standards: IEC 60909, CEI 60502-2, NFC 13-200, VDE 276 and IEC 61363 (for the design of marine and offshore electrical networks).


Time saving:

  • Caneco HT automatically produces network single-line diagrams and calculation notes, thus reducing multiple data entry and risk of errors.


Tailored to global markets:

  • Caneco HT allows the design of international projects thanks to its multi-standard and multi-language options.

Other features

+
Integration of wind turbines with asynchronous alternator:

Integration of a new wind farm-type source based on asynchronous alternators with calculation of short-circuit currents according to IEC 60909 and calculation of voltage drops.

Integration of speed variator:

Integration of a new receiver "speed variator" with calculation of short circuit currents according to IEC 60909 and calculation of voltage drops.

Drive data can be defined by entering user data or by selecting a manufacturer catalog.

Label integration for relays:

Possibility to add on the general single-line diagram, an informative label for the Phase and Homopolar relays, integrating the different current thresholds and timers.

Manufacturers catalog:

  • Variable speed drives: Altivar 1200 series and Altivar 6000 series (Schneider Electric)
  • HT cells: SM Airset Cells & Rm Airset cells (Schneider Electric)
  • Transformers: Addition of 36 kV transformers (Schneider Electric)
  • Relay: REF 615 (ABB) & Easergy P1, P3, P5.


Features

Docs & Videos



General introduction

Download


Download

To download the latest version of our software, you need to log in to your account in the “Downloads” section.

Would you like to be redirected to ALPI website ? → ALPI Website.




Training


Training

Get an in-depth overview of our electrical engineering software by requesting the training course that suits you.

We’ve been providing training for electricians for over 35 years. We understand that a good atmosphere and proper equipment significantly accelerate the learning process. That’s why, in addition to professional trainers, appropriate equipment, and software, our electrician courses offer numerous options that make learning enjoyable.

→ Fill out the training request now




Caneco HT

Annual subscription

Calculation of IK1 with IC

Considering the capacitive current IC in the calculation of the phase-to-earth fault IK1.

Standard assigned characteristics for CT and VT out of catalogue

When choosing a CT or VT out of catalogue, a list of normalized values is proposed for each assigned characteristic (Ur, IP/is, Ith, precision power, ALF…)

Integration of a generic protection relay with functions 50/51, 50N/51N,50G/51G

  • Addition of a generic relay with max phase current (50/51) and max zero sequence (50N/51N, 50G/51G) functions.
  • The relay has three thresholds with wide adjustment ranges and very fine pitches.
  • The first threshold may be of DT or IDMT type (13 standardized curves).

Drop-down list of standard voltage choices for network feeders and switchboards

Addition of a list of standardized voltages (according to NF C13-200 standard) for network feeders and switchboards.

Other features

  • Add a box in the “network feeder” window to identify public distribution substations.
  • Add a box for IB (base current) for connection type links such as cables.
  • mproved setting of general protection (in addition to the 0.8*IK2min, apply the 8*IB rule).

New Manufacturer catalogues

  • Fuse: Schneider Electric 2020
  • Relays: ABB : REM 615, RET 615 et REF 620 ranges.
BUY NOW

Related products

  • Caneco BT

    Caneco BT is a software for automated calculations, sizing, and diagrams of low voltage electrical installations.

    → Learn More
  • Caneco BIM

    Caneco BIM is a Revit® plugin that allows electrical information to be exchanged between a digital model and the Caneco software range.

    → Learn More
  • Caneco IMPLANTATION

    Caneco Implantation is an AutoCAD® plugin that enables the implantation of electrical material in 2D or 3D, as well as automated cable routing.

    → Learn More